Vokera linea 24 error code 02

2 KB, 642 views) Last edited by jd; at 09: 10. I have gone through the manual myself last night, and the boiler seemed to have gone crazy, after one hour playing with it, I came across all sorts of errors, CO, 02, 03, 07. View and Download VOKERA Linea 24 installation & servicing instructions manual online. THE LINEA RANGE Combined Central Heating and Domestic Hot Water Appliance. Linea 24 Electric Heater pdf manual download. Linea 1 Contents Page. 24 hours, the pump, fan, & valve actuator, are. boiler displays a unique fault code that helps iden- tify where the fault lies. I have a linea 24 that was installed 12 years ago. Serviced annually by a decent plumber. In the last few years it has taken a bit off money off us, new heat exchanger, valve. Free help to mend, fix or repair - reset vokera boiler. Hi all after fitting a new rad I was constantly having to top up the central heating loop, so ( thanks god it wasnt piping connector loose in the wall) Turns out it was actually the PRESSURE RELEASE VALVE i ordered a new one and installed it, but thought id list what happen as to help someone else.

  • Server error code 50130
  • Ora 00600 internal error code arguments keltnfy ldminit 46
  • Code error on honda civic radio says
  • Error code in xbox 360
  • Webdav error code 404
  • Gumh v13 error code


  • Video:Vokera linea error

    Error linea vokera

    i have a vikera linea 24, when running hot water the pressure increases to 3 bar then the relief opens with a bang, boiler then goes into fault code 07 then 02. pressure settles at 1 bar, after 10 mi. Hi, the clock on my Vokera Linea 24 has stopped working. I have had problems with the thermostat which now seems OK. I can control the boiler by turning the stat up or down. More than one and a half million Vokèra boilers and heating products have brought warmth and comfort to customers across the UK & Ireland. Vokèra is an industry leader in quality home heating solutions, offering a comprehensive product range for domestic home heating and light commercial applications. Went to check out vokera linea 28 today the boiler fires up stays lit for no more than 10 seconds and goes out in both ch and dhw modes Has anyone come across this fault Boiler goes red and code 01 is displayed but this code is failure to ignite and the boiler does ignite it just does not stay lit. Client complained about hot water problems on Vokera Linea 24. At first sight it seemed like a blocked hot water plate giving following symptoms: hot water fluctuating between hot and cold - classic blocked heat exchanger symptom occasionally. See more like this Vokera Linea 24 & 28 Boiler Bobbin Shutter For 3 Way Valve & Seating Washer 2910 Customs services and international tracking provided VOKERA LINEA 24 28 & LINEA PLUS GAS VALVEWASSee List Below. Fault Code System Behaviour; AL10, AL20, AL21, AL26, AL28, AL34 : Try resetting the boiler, if the fault reoccurs you need to contact a professional. Details about Vokera Linea 24 28 Plus AG Overheat High Limit Thermostat StatVokera Linea 24 28 Plus AG Overheat High Limit Thermostat StatFor this item, the seller provides:. Vokera linea 24 Finding your Gas Appliance Spares on our website You can locate the part you require in a number of different ways, you can select from the choice of spares below or alternatively you can use the filters on the left in the ‘ refine your results’ section.

    Intermittent fault tends to do it once warmed up, if turned off and on again at mains may go for a few days working fine then back to this fault. Are you experiencing a boiler fault with your Mynute HE boiler? Your Vokera boiler is equipment with a built in fault diagnosis system, this means if your experiencing a fault then your boiler will display a fault code. Vokera Boiler Manuals / Instructions. Download a copy from our library, if your boiler is not listed Contact us and we will do our best to help you. Boiler Fan Repair Ideal Gloworm Bosch Worcester send £ 3 to com for bearing kit - Duration: 6: 59. John Gaffney 49, 616 views. 07 fault code on vokera linea Boiler will start up for very brief time if left off for a while but won' t run long enough to heat up central heating, fault code 07 showing Posted by Neil Durrant on Dec 15,. Linea 24 & 28 1 These appliances are designed for use with a sealed heating system only and are not in- tended for use on an open vented system. The provision of stored domestic hot water is. Vokera Linea 07 Fault Code See by Mbear you' d have been cheaper buying a prv from a ch spares place. Hope However, the fan will continue to run until Vokera Boiler Flashing 07 i wont get any sub for a replacement.

    Literature Find all Vokèra manuals & literature in one place. Click here to go straight to the discontinued Vokèra products. Current Product Literature. ideas its a Vokera linea hd combi boiler, not the greatest i know but hey ho. Posted on: : 45: 07 _ _ Older post · Trained and talented plumbers of Vaillant Boiler Repair London boiler Honeywell boiler Halstead boiler Keston boiler Ideal boiler Vokera boiler. I have a vokera linea 24 and have had it for 6 years with a catelogue of problems. Including expansion tank, diverter valve seal going twice and the motor that sits onto of this valve going 3 times. Inline sensor once. Reply With Quote# 7 craig Guest Re: Vokera linea Code 07 Originally Posted to fix Polaroid products. flexihose joining the pump manifold to the exp vessel.

    com provide the answers. VOKERA linea installation and servicing instructions. pdf VOKERA linea plus ag users instructions. pdf VOKERA hydra installation and servicing instructions. Re: Combi boiler fault - Vokera Linea 24 Does sound like an airlock in the system Just check each radiator in turn and fill the system up to the requisite pressure. Hi can anyone help with a problem I& # 146; m having with a Vokera linea 28 combi, it& # 146; s displaying code 3 flue/ fan problems, but will work ok when case is open. code 07 means the primary thermister is open circuit, it is not able to sense the resistance through it, it is located on the right hand side of the main heat exchanger with two brown wires going to it, should have a resistance of around 12kOhms at room temp( 20 degs) needs to be drained down to be replaced, hope this helps. Listed below are all the manuals for Vokera. Just click on the model or the Gas council number and the manual will download at the bottom of the page. After you have downloaded the manual double click on the download for the manual to open, if you want to save the download right click. 12 FAN ( see fig.

    24) Carry out component removal procedure as de- All dimensions in mm. Unclip and remove the air chamber cover. Disconnect the electrical plug from the fan. Welcome to our DIY, home improvement and do it yourself help, tips and advice website. We have literally tonnes of help information and advice on all aspects of DIY. Home > vokera boiler > vokera boiler error 07 Vokera Boiler Error 07 ' Plumbing and Central Heating' started by dj1975,. I have a vokera linea 24 combi, it won' t relight ( show code 01) after an interuption to the gas supply ( due to a fault on a fireplace). read more Andrew Smith. Vokera Linea fault code 40/ 41 ( Vokera Compact code A04) The Fault: The codes above mean your boiler’ s pressure levels are low. Sometimes this can happen if there’ s a leak, or if an air bubble has found its way into the system. Page 1 of 2 1 2 Next > arundel gas services Joined: Messages: 14 Thanks Received: 0 Country: i have a 2 year old linea that lock out on 02 about every 2 to 3 weeks it is the one with the water pressure s/ w i have tryed changing, pump, thermistors, o/ h stat both display and main pcb and water flow s/ w there is a bypass and all the. Dismiss Notice Vokera Linea 24 ' ERROR CODE 01' Discussion in ago # Advertisement Topic Closed This topic has been closed to new replies. High pressure on your boiler pressure gauge. 379 görüntüleme 2: 59 Vaillant Ecotec Mk Lisansı Daha fazla göster Daha az göster Yükleniyor.